955 compact PTO will not engage
![]() | mixontonya
Join Date: May 2015 Posts: 3 Jonesboro, AR ![]() |
2015-05-19 192807
I have a JD 955 tractor and the PTO will not engage. There was a blown fuse and I replaced it but it still won't engage. Help!
Reply to |


955 compact PTO will not engage
![]() | PaulChristenson
Join Date: Dec 2007 Posts: 83 Vermont ![]() ![]() |
2015-05-19 192808
Have you checked the seat safety switch?
First, remove the wiring harness connecetor from the seat switch and install a jumper wire from the Yellow wire to the Pink/White wire. Now try the PTO... if it works, then the seat switch is bad. If it still doesn't work, access the TDC Module and disconnect the 4-pin harness. Install a jumper wire from the Yellow wire to the Blue wire on the tractor side of the harness. If the PTO then works, the TDC module has crapped out. ....
Reply to |


955 compact PTO will not engage
![]() | mixontonya
Join Date: May 2015 Posts: 3 Jonesboro, AR ![]() |
2015-05-24 192825
The tractor won't start if the seat switch doesn't work, but it is starting so I don't think that's it. Any other suggestions? Or was the second part of your message another suggestion? I'm gonna have to decipher that one, haha. I've got a lot to learn. ....
Reply to |


955 compact PTO will not engage
![]() | jdgreen
Join Date: Jul 2003 Posts: 232 Maryland ![]() |
2015-05-25 192830
Actually the tractor will start with a bad seat switch. It only affects the pto. ....
Reply to |


955 compact PTO will not engage
![]() | jtdday
Join Date: Jun 2013 Posts: 25 USA ![]() |
2015-05-26 192838
If you had tried all else, you might look at one other. Look on the right side of the trains housing, there should be two wires going into the PTO solenoid. This solenoid might be shorting out when you pull out the PTO button thus blowing the fuse. PS this unit will set you back about $140.00 so test it first. Good Bless! ....
Reply to |




Share This