Go Bottom Go Bottom

JD 4020 24 volt system

View my Photos
sagedog
Join Date: Jun 2006
Posts: 16 Berthold, ND
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2010-10-13          174551

A little advice and knowledge requested here. I have a 1967 JD 4020. I think it still has the original 24 volt electrical system. I read somewhere that the starter and alternator run 24 volts but the lights and accessories run 12. I want to put in a cab heater but don't know if I should get a 12 or 24 volt heater.

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



JD 4020 24 volt system

View my Photos
auerbach
Join Date: Sep 2007
Posts: 2168 West of Toronto
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster  View my Photos  Pics

2010-10-13          174560

Didn't know that about Deere. If it has two batteries and you're getting a water heater, the only electrics would be a blower fan so I'd get a 12.

If an electric-element heater, either. If you can find one, 24 would be good. Otherwise I'd draw the 12 out of both batteries together. ....

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



JD 4020 24 volt system

View my Photos
Murf
Join Date: Dec 1999
Posts: 7249 Toronto Area, Ontario, Canada
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster  View my Photos  Pics

2010-10-13          174562

First off, I think you'll find if your machine is a 24 volt model, you likely have a generator, not an alternator.

But if you have a 24 volt system, and can get a heater with a 24 volt blower, it would be better to go that way. The 24 volt model will draw less current and be easier on that old generator and the batteries.

You should also put a pair of electric battery warmers on that old girl too, it's a bunch easier on them in cold weather, the old generators don't put out a lot of power compared to a generator.


Best of luck. ....

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



JD 4020 24 volt system

View my Photos
hardwood
Join Date: Dec 2002
Posts: 3583 iowa
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2010-10-13          174567

Sage;
I had a 4010 an older model,( 61-62?) sister to your 4020. I do know it had Deere's 24/12 system. The generator and starter were 24 the rest was 12. The early 4010's had no circut breakers so they were famous for as mine did catching fire if a short occured. I'm not sure if any 4020's were 24/12, but as Murf said if it has an alternator it likely is an all 12 system.
Frank. ....

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



JD 4020 24 volt system

View my Photos
sagedog
Join Date: Jun 2006
Posts: 16 Berthold, ND
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2010-10-13          174571

Thanks for the quick replies everyone. I will check on your suggestions. ....

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo