JD4300 will not start no power
![]() | LDS2121
Join Date: Mar 2008 Posts: 9 Huntington Texas ![]() |
2008-03-24 152376
Hi all.
Thanks in advance for the help .
I have a 1998 JD 4300 with hydrostatic. I put a new battery on it today and went to move some dirt. I was moving dirt with the front bucket and stalled the tractor and it died. I know needed to put in lower gear. Anyway I it has stalled before and I had to push F/R pedals to line up the safety switch so it will crank. This time it will not crank. I do not have any power. Meaning It will not turn over, solenoid will not click , headlights will not work. I have checked the battery connections and all are good. Is there a master fuse somewhere that may have blown?
Reply to |


JD4300 will not start no power
![]() | LDS2121
Join Date: Mar 2008 Posts: 9 Huntington Texas ![]() |
2008-03-24 152378
Oops. False alarm.I had a tight connection on the battery but the terminal was corroded on the inside. My son said to clean the connection, we did and it started right up.
Thanks ....
Reply to |


JD4300 will not start no power
![]() | kthompson
Join Date: Oct 2005 Posts: 5275 South Carolina ![]() ![]() |
2008-03-25 152384
Congratulations on your son! kt ....
Reply to |