JD 4710 E-Hydro diesel popping main fuse
Forrest
Join Date: Oct 2007 Posts: 2 Oak Hill WV |
2007-10-05 146570
I have a JD 4710 E-hydro with 1300 hours on it. When the outside temp is above 80 and I am running it, the main 30 ampre fuse keeps blowing. I have cleaned all the screens, etc. and checked everything. The TEMP gauge shows fine. The tractor will idle all day, no problem.
Reply to | Quote Reply | Add Photo
JD 4710 E-Hydro diesel popping main fuse
candoarms
Join Date: Mar 2007 Posts: 1932 North Dakota Pics |
2007-10-05 146577
Forrest,
When main fuses begin blowing, it is usually due to a loose electrical connection.
The extremely high electrical resistance caused by the loose connection, also causes the amperage to increase by a tremendous amount.
Look for a loose wire, corrosion, or even a large wire that is hanging on by only by a few thin strands. (nearly broken)
Joel ....
Reply to | Quote Reply | Add Photo