cooling fan

View my Photos
pilotboat
Join Date: Mar 2009
Posts: 2 Indiana
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2009-03-15          161081

My 2002 gator 6X4 gas water cooled kawasaki engine is over heating and the electric cooling fan wont turn on. I have replaced the temperature sensor in the radiator but, the electric cooling fan wont turn on while in the radiator. I pulled the temperature probe out of the radiator and heated it up with a heat gun and this DID make the fan turn on. The top hose on the radiator is hot and the bottom one is cold. Any ideas?

Thanks,
Kurt


Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



cooling fan

View my Photos
earthwrks
Join Date: Dec 2003
Posts: 3853 Home Office in Flat Rock, Michigan
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster  View my Photos  Pics

2009-03-15          161082

Sounds like the thermostat to me. ....

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



cooling fan

View my Photos
gatoraider
Join Date: Nov 2008
Posts: 544 Maryland
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2009-03-16          161095

If your top radiator hose is hot all the way to the radiator and your bottom hose is cold you must have a clogged radiator, or a clogged lower hose. If your top hose is just hot next to the motor and not all the way to the radiator you may not be pumping coolant. You need to remove the bleeder screw in the intake manifold next to the 90 fitting for the carb ( 12 mm wrench ) and see if there is coolant present. If not fill 'er up, put the screw back in and try it. I've had air locks occur multiple times there so try it and check it. Be sure your temp light is working, it should come on when the ignition is in the start position. I've never seen a water pump fail to pump, so I doubt if it's that. ....

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



cooling fan

View my Photos
jbjpam
Join Date: Jun 2007
Posts: 39 Mid Michigan
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster  View my Photos  Pics

2009-03-16          161124

Gatoraider has it correct. Exact same problems I used to have with mine (fan and hoses) You must fill that little hole to the top. I did it while running and water pumping to be sure it was full. No problems from then on. I also put an override toggle switch on the fan control just in case. It would let it run all the time if I wanted. ....

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo