Ford 1210 Tractor Hydraulic lines blow off
tractor56
Join Date: Dec 2012 Posts: 3 michigan |
2012-12-04 185604
Need help hydralic line keeps, blowing off hydrostatic oil cooler. any ideas thanks
Reply to | Quote Reply | Add Photo
Ford 1210 Tractor Hydraulic lines blow off
Rungreen
Join Date: Dec 2012 Posts: 11 Missouri |
2012-12-16 185735
Start with changing the filter. Cut it apart and pull the filter media out to see what is in it. Is the oil running hot? Are you using the Ford/NH synthetic oil designed for this machine? If the oil is to spec and the temp seems ok, get a guage to check the pressure to the cooler. Be careful doing this as the pressure may be high. A service manual is invaluable in this instance. If all checks fine, try running it on the low side. I know it may be slow for what you are doing, but the bottom side of high is a little soggy and generates a lot of heat and the pressures will spike with load. My dad had one of these and I maintained it for 14 years for him. ....
Reply to | Quote Reply | Add Photo
Ford 1210 Tractor Hydraulic lines blow off
tractor56
Join Date: Dec 2012 Posts: 3 michigan |
2012-12-17 185736
Thank you I checked the pressure with a gage and it was fine. I bought the tractor this way. The cooler was not bolted to anything just sitting out front, I welded a bracketto it an bolted it back onto the clutch in front seems to be working also changed the fluid looks like maybe it had the wrong fluid in it seemed thicker then the ford fluid thanks for the reply' ....
Reply to | Quote Reply | Add Photo
Go Top
Share This