PTO shaft for 24 RAD Debris Blower
crunch
Join Date: Jan 2007 Posts: 271 Niagara County, NY Pics |
2011-11-06 181097
I just picked up a RAD debris blower that I got off ebay. I have no paperwork for it but I am guessing from the housing that it has a 24" diameter fan. I didn't come with a PTO shaft. I have 27hp at the PTO on my JD4310. Would a PTO shaft rated for 16hp at Northerntool.com do the job? Or do I have to get the one rated at 35hp?
Joe
Reply to | Quote Reply | Add Photo
PTO shaft for 24 RAD Debris Blower
hardwood
Join Date: Dec 2002 Posts: 3583 iowa |
2011-11-06 181099
Crunch;
I don't think I'd feel safe with that light of a PTO shaft.
What is a derbris blower, or is it a snow blower? Does it run off the rear or mid PTO shaft?
The mid PTO turns at 1900 RPM, I think. You can push a lot more horsepower thru a faster spinning shaft. Frank. ....
Reply to | Quote Reply | Add Photo
PTO shaft for 24 RAD Debris Blower
crunch
Join Date: Jan 2007 Posts: 271 Niagara County, NY Pics |
2011-11-06 181101
Hello Frank, it is a leaf blower. Just a fan that pushes air and it drives off the rear PTO. It takes a spline connection at the implement. ....
Reply to | Quote Reply | Add Photo
PTO shaft for 24 RAD Debris Blower
hardwood
Join Date: Dec 2002 Posts: 3583 iowa |
2011-11-06 181108
Crunch;
Guess i never saw a PTO leaf blower, It doesn't seem it would take much power to operate it. But to be on the safe side I think I'd opt for the heavier shaft.
Frank. ....
Reply to | Quote Reply | Add Photo
PTO shaft for 24 RAD Debris Blower
kthompson
Join Date: Oct 2005 Posts: 5275 South Carolina Pics |
2011-11-08 181126
For the $10 difference in price would buy the 35 hp rated shaft. The 16 might be sufficient on this blower but the next item you would probably then have to buy the higher rated shaft.
Do check for proper length before you buy and certain don't install too long or too short a shaft for too long WILL damage something and too short can also.
....
Reply to | Quote Reply | Add Photo
PTO shaft for 24 RAD Debris Blower
crunch
Join Date: Jan 2007 Posts: 271 Niagara County, NY Pics |
2013-08-24 187925
I have the answer. I purchased the PTO shaft rated for 16 hp. It almost lasted 2 years. Yesterday the universal cross broke from the torque when I engaged the PTO. It had probably weakened or cracked over time. Lesson learned!
Crunch. ....
Reply to | Quote Reply | Add Photo
PTO shaft for 24 RAD Debris Blower
kthompson
Join Date: Oct 2005 Posts: 5275 South Carolina Pics |
2013-08-25 187931
Thanks for the update and trust nothing got damaged. ....