jimna 2524 busting 30 amp fuse wont start
troycattt
Join Date: Apr 2007 Posts: 3 austin, tx |
2007-04-14 141311
I have a small jimna thats not a year old. I can't start it because everytime I try it blows the green 30 amp fuse. What can be done about this?
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
RanchHand
Join Date: Apr 2005 Posts: 37 Virginia / North Carolina Line |
2007-04-15 141317
Could be a number of things.....
The first thing I would check is the ingition switch.
Ronald
Ranch Hand Supply
....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
troycattt
Join Date: Apr 2007 Posts: 3 austin, tx |
2007-04-15 141325
Thanks for responding Ronald,
What am I looking for on the ignition switch. I'm a total novice. I just don't have the money to pay someone to fix it. I'll get out the manuel to see what the ignition switch looks like.
Do I need to test it? How do I do that if I can't get it to start?
Also, I think it happens more when it's cold outside. It doesn't seem to happen when it's above 75 outside.
Could it have to do with the glow plug heating system?
Thank you for your input!
I really appreciate the help
Troy ....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
RanchHand
Join Date: Apr 2005 Posts: 37 Virginia / North Carolina Line |
2007-04-16 141336
Do you know if it blows the fuse when you....turn the key on ?, when you heat the glow plugs , when you turn to crank? or blows while cranking?
Ronald
Ranch Hand Supply
....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
troycattt
Join Date: Apr 2007 Posts: 3 austin, tx |
2007-04-16 141346
Hey Ronald,
It blows it the second I turn the key to start it. It does not crank at all. Just a little click sound which is the fuse breaking.
....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
RanchHand
Join Date: Apr 2005 Posts: 37 Virginia / North Carolina Line |
2007-04-16 141347
It's hard to cover everything in a post but,
Take the litte/small wire off the starter solenoid and make sure it is not touching anything and see if it will blow the fuse then.
If it does ... odds are ingition switch is bad.
If it blows only with the wire connected to the solenoid then odds are the solenoid is bad.
Also, the small wire off the solenoid could be contacting ground ?
let us know
Ronald
Ranch Hand Supply
....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
Dino_JMWA
Join Date: Apr 2008 Posts: 2 Australia |
2008-04-15 152984
There are two positions on the ignition switch to activate the starter. One in the normal position like a car and one full anticlockwise. Try cranking the engine by turning the key full anticlockwise. This will not activate the glows but if it cranks then the following may be your solution. There is a point just before start where Jinma ignitions tend to activate both the starter solenoid and the glow plugs at the same time. If you turn the key too slow after activating the glow plugs both the solenoid and glow plugs together will draw too many amps and blow the fuse. This can be overcome by turning the key to glow then quickly turning the key to start. Alternatively turning the key to glow then turning the key full anticlockwise to activate the starter only. Once running turn the key to on. ....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
auerbach
Join Date: Sep 2007 Posts: 2168 West of Toronto Pics |
2008-04-15 152991
You can bypass the switch in the meantime, and if it runs OK that way, that should tell you it is the switch. Learn how to "jump" start it.
You could use a screwdriver blade or anything metal, but I suggest get a few inches of thick wire insulated except at the two ends about 1/4 inch. Learn what two starter terminals you jump. A diesel doesn't need the ignition to be on, only the battery doesn't get charged while running that way. ....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
Murf
Join Date: Dec 1999 Posts: 7249 Toronto Area, Ontario, Canada Pics |
2008-04-15 152992
Quote:
|
A diesel doesn't need the ignition to be on, only the battery doesn't get charged while running that way. [/QUOTE]
That's not quite true in most cases.
Almost all 'modern' tractors have a fuel shutoff relay to stop the engine when the key is shut off. If there is no power to that relay, the fuel pump will never generate pressure because the fuel will just get dumped back to the tank instead of spraying out the injectors.
No power to the relay means no fuel.
Best of luck. ....
Reply to | Quote Reply | Add Photo
jimna 2524 busting 30 amp fuse wont start
greg_g
Join Date: Jan 2004 Posts: 1816 Western Kentucky Pics |
2008-04-15 153001
Quote:
|
By the way guys, you're responding to a year old topic
//greg// ....
Reply to | Quote Reply | Add Photo
Go Top