New altenator Yanmar 169
jman50
Join Date: Jul 2018 Posts: 2 Florida |
2018-07-02 197829
I am replacing the original alternator on a Yanman 140YM69 (bad bearings) with new HAL-1215 alternator. Orginal wiring on old alternator had 2 wires wired with wire nuts no plug to tractor wiring. I installed new alternator, then with tractor running I now measure 25 volts AC at new alternator. My question as this is AC volts , I assume polarity should not be of concern when connecting to the tractor wiring? The other question is the 25 volts normal at a high RPM of tractor it looks pretty constant even when RPM reduced? Wires travel to what is shown on print as a current limiter. Any advice would be appreciated. I am trying to be a little cautious here before connecting wires to current limiter. Thanks
Reply to | Quote Reply | Add Photo
New altenator Yanmar 169
jman50
Join Date: Jul 2018 Posts: 2 Florida |
2018-07-02 197830
New alternator AL 1215 ....
Picture Link
Reply to | Quote Reply | Add Photo
New altenator Yanmar 169
jman50
Join Date: Jul 2018 Posts: 2 Florida |
2018-07-02 197831
Print designated current limiter ....
Picture Link
Reply to | Quote Reply | Add Photo
New altenator Yanmar 169
jman50
Join Date: Jul 2018 Posts: 2 Florida |
2018-07-02 197832
Print from tractor manaual ....
Picture Link
Reply to | Quote Reply | Add Photo
New altenator Yanmar 169
winston1
Join Date: Sep 2010 Posts: 85 gilmer,texas75645 |
2018-07-03 197833
https://www.hoyetractor.com/support/knowledgebase.php?article=44
25 volts is fine. ....
Reply to | Quote Reply | Add Photo
New altenator Yanmar 169
BigRol
Join Date: May 2015 Posts: 4 Cape Breton |
2018-07-03 197834
25 volts AC? on 12 volt DC system, not good, your voltage regulator is probably the rectifier also and not working or bypassed. you will smell the battery and eventually fry it with AC voltage, your alternator is full fielding at 25 volts,
Hope this helps ....
Reply to | Quote Reply | Add Photo
New altenator Yanmar 169
winston1
Join Date: Sep 2010 Posts: 85 gilmer,texas75645 |
2018-07-03 197835
His dynamo puts out ac voltage, the regulator/rectifier changes it to about 14dc volts. Don't think he wanted to hook up the regulator until he was convinced it didn't make any difference which way the two wires hooked up. ....
Reply to | Quote Reply | Add Photo
New altenator Yanmar 169
BigRol
Join Date: May 2015 Posts: 4 Cape Breton |
2018-07-03 197836
Lol, that sounds better I was assuming he was checking at the battery for voltage. ....
Reply to | Quote Reply | Add Photo
Go Top