AnnBrush Photo Album and Profile

Post hole digger shear bolts
Post hole digger shear bolts

Remember there should only be one of these. Use two and they will not shear as designed - I learned the hard way.

Neutral not switched at transfer switch
Neutral not switched at transfer switch

Neutral is not switched by the neutral as floating neutral generator requires service neutral for ground reference

Neutral should be switched
Neutral should be switched

Here neutral should be switched as paralell current is created on EGC and neutral. Note the difference between this and photo 2 is that the neutral is bonded to the frame at (in) the generator.

430 Loader latch
430 Loader latch

Pic of the latch in question, it is part 4 in the diagram.