2004-03-21          80596


Hi guys got a question, have a grider pump, giving me trouble again ,first pump lasted three months second pump 3.5 years ,is this normal? have been using gould brand pumps first pump #gp2010 second rgs2012, are these pumps good or bad ?



Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



grinder pump bad

View my Photos
TomG
Join Date: Feb 2002
Posts: 5406 Upper Ottawa Valley
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2004-03-22          80688


Sorry I don't know what a grinder pump is. I started out thinking hydraulics and wrote some bumphf but now I think it may not be relevant. ....


Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



grinder pump bad

View my Photos
blizzard
Join Date: Jul 2003
Posts: 282 Central Maine
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster  View my Photos  Pics

2004-03-22          80693


Tom,
This is a waste pump for use where the septic field or sewer is higher than the 'collection point'
bliz ....


Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



grinder pump bad

View my Photos
hardwood
Join Date: Dec 2002
Posts: 3583 iowa
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2004-03-22          80695


Several years ago we were giong to build a house, but the spot we liked would have required a lift pump for the sewer. I called the local septic service guy, his answer at that time was avoid the lift station if possible, that they can be a problem, so we moved the house further up the hill and avoided it. But perhaps by now the pumps have been improved. Best of luck, Frank. ....


Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



grinder pump bad

View my Photos
TomG
Join Date: Feb 2002
Posts: 5406 Upper Ottawa Valley
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2004-03-22          80696


Thanks Bliz. Some friends had one of those and it sure isn't good for them to fail. Theirs didn't but our codes require the pumps to be run off a GFI circuit (same as all outside outlets). Really dump because the GFI kept tripping. Apparently it's common for contractors to install the GFI's for inspection only. I think my friends lived there for almost 10 years and I never heard they replaced the pump, but I have no idea what make it was. I'd think something was wrong with a failure at 3.5 years. There an expression for extreme worry or anxiety that may apply but I don't suppose that joking around is very helpful here. ....


Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



grinder pump bad

View my Photos
blizzard
Join Date: Jul 2003
Posts: 282 Central Maine
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster  View my Photos  Pics

2004-03-22          80699


Goulds makes rugged pumps!
I found the link (below) and one thing that's important is the pump must be fully submerged for best life. It is rated for continuous or intermittent operation, but limited to 10 evenly spaced starts per hour. Bearing life is 30,000 hours, so check your wiring and controls. Is the basin it is in is too small?
Perhaps the float or pressure switch is sticking or improperly set, causing over-heating.
bliz

Look For Product Bulletin (BRGS2012.pdf) ....


Link:   Hit_Flows_Uphill

 

Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



grinder pump bad

View my Photos
unit5alive
Join Date: Jul 2003
Posts: 250 Latrobe Pa
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster

2004-03-22          80747


Thanks guys, seams to work now has a lot of junk floating around ,on top of water,maybe held float down,setting off alarm? ....


Reply to | Quote Post Reply to PostQuote Reply | Add PhotoAdd Photo



grinder pump bad

View my Photos
Peters
Join Date: Feb 2002
Posts: 3034 Northern AL
TractorPoint Premium Member -- 5 Tractors = Very Frequent Poster  View my Photos  Pics

2004-03-23          80815


I had a house in Sturbridge MA on the lake. The town decided to get rid of septic systems. They decided to go to a grinder system for the whole area and save on pipe and excavation costs. I sold the house before the system was installed but had a number of discussion with the engineers. Before they decided to install the system I had paid for the design of a pump septic system.
All the engineers were talking 20 years for these pumps.
I can not say the 2K in septic education was well spent, but in political areas sometimes you don't have a choice. ....